DEI57SC
5.7” touch screen
controller/monitor with single load cell input DEI57SM
5.7” touch screen
monitor only with single load cell input DEI57DC
5.7” touch screen
controller/monitor with dual load cell input DEI57DM 5.7” touch screen monitor only with dual load cell input
·
Load
cells: Depends on Model Number ·
Resolution:
24 bit. ·
Accepts
a 12 point Calibration ·
Filtering
/ Count By Settings ·
Tare
button: YES ·
On/Off
switch: YES ·
Control
type: On/Off ·
Control
devices: Solid State Relays (25 Amps) ·
Configurable
Control Options (Performance) ·
Test certificate application: included (Required:
Excel 2007 & Ethernet Port on PC) ·
PDF
Certificate, CSV Data File ·
Ethernet
Connectivity ·
Password
Protection ·
Sampling
Rate: Auto-Selected(100
per sec max)
In certain situations this system can be operated from the computer on your desk. Ask us how. When the test is complete the following test certificate is saved to the computer hard drive.
Options: ·
RFID
and Barcode readers ·
Elongation (Data
logged and Graphed vs. load) ·
Audible
Enunciator · Custom Configurations (Call 800-621-8276)
This system allows the operator to run a test in auto control mode or manual mode. Data logging is performed within the touch screen controller and then transferred when the test is complete. This allows for faster sampling rates and data retransmission in an event of transmission errors. Auto stop logging stops the data logging at a predetermined low value as not to log unnecessary data. Hold Target Time tells the controller the duration of time that the load must be held, before pressure is released (Auto Mode).
Pictured
above is the ON/OFF control scheme. The
operator enters the first and second steps in percent of the target load
and the pause in between in seconds (0.1 sec resolution). Operation The
system will energize relay 1 to allow the force to increase up to step 1
and pause. After the pause
the system will energize relay 1 again until the system reaches step 2.
Then the system will turn relay 1 on and off in short bursts until
the target load is reached and will keep cycling relay 1 to hold the
pressure at the target load until the hold target time is met. Finally the
load is released, data is transferred and the appropriate files are
created and saved.
Mono Color Version: DEI24SM 2.4” display/monitor with single load cell input DEI24DM 2.4” display/monitor with dual load cell input
·
Load
cells: Depend on Model ·
Resolution:
24 bit. ·
Accepts
a 12 point Calibration ·
Filtering
/ Count By Settings ·
Tare
button: YES ·
On/Off
switch: YES ·
Test
certificate application: included (Required: Excel 2007 &
Ethernet Port on PC) ·
PDF
Certificate, CSV Data File ·
Ethernet
Connectivity · Password Protection · Sampling Rate: Auto-selected (10 per second) This
system allows the operator to run a test in manual mode. Data logging is
performed within the 2.4” display/ monitor and then transferred when the
test is complete. This allows
for faster sampling rates and data retransmission in an event of
transmission errors. Auto
stop logging stops the data logging at a predetermined low value as
not to log unnecessary data.
Panel Meter Version:
Front Cover
Inner Panel (Pictured Data Logging Only) Please contact Ted for more info 800 621-8276 or 847 671-7676. |
|