DEI57SC   5.7” touch screen controller/monitor with single load cell input

DEI57SM   5.7” touch screen monitor only with single load cell input

DEI57DC  5.7” touch screen controller/monitor with dual load cell input

DEI57DM   5.7” touch screen monitor only with dual load cell input

·       Load cells: Depends on Model Number

·       Resolution: 24 bit.

·       Accepts a 12 point Calibration

·       Filtering / Count By Settings

·       Tare button: YES

·       On/Off switch: YES

·       Control type: On/Off

·       Control devices: Solid State Relays (25 Amps)

·       Configurable Control Options (Performance)

·       Test certificate application: included

(Required: Excel 2007 & Ethernet Port on PC)

·       PDF Certificate, CSV Data File

·       Ethernet Connectivity

·       Password Protection

·       Sampling Rate: Auto-Selected(100 per sec max)

 

In certain situations this system can be operated from the computer on your desk.  Ask us how.

When the test is complete the following test certificate is saved to the computer hard drive.

 

Options:

·       RFID and Barcode readers

·       Elongation  (Data logged and Graphed vs. load)

·       Audible Enunciator

·       Custom Configurations (Call 800-621-8276)

 

      This system allows the operator to run a test in auto control mode or manual mode. Data logging is performed within the touch screen controller and then transferred when the test is complete.  This allows for faster sampling rates and data retransmission in an event of transmission errors.  Auto stop logging stops the data logging at a predetermined low value as not to log unnecessary data. Hold Target Time tells the controller the duration of time that the load must be held, before pressure is released (Auto Mode).

 

 

 

 

Pictured above is the ON/OFF control scheme.  The operator enters the first and second steps in percent of the target load and the pause in between in seconds (0.1 sec resolution).

 

Operation

The system will energize relay 1 to allow the force to increase up to step 1 and pause.  After the pause the system will energize relay 1 again until the system reaches step 2.  Then the system will turn relay 1 on and off in short bursts until the target load is reached and will keep cycling relay 1 to hold the pressure at the target load until the hold target time is met. Finally the load is released, data is transferred and the appropriate files are created and saved.

 

 

Mono Color Version:

DEI24SM   2.4” display/monitor with single load cell input

DEI24DM   2.4” display/monitor with dual load cell input

·       Load cells: Depend on Model

·       Resolution: 24 bit.

·       Accepts a 12 point Calibration

·       Filtering / Count By Settings

·       Tare button: YES

·       On/Off switch: YES

·       Test  certificate application: included (Required: Excel 2007 & Ethernet Port on PC)

·       PDF Certificate, CSV Data File

·       Ethernet Connectivity

·       Password Protection

·       Sampling Rate: Auto-selected (10 per second)

This system allows the operator to run a test in manual mode. Data logging is performed within the 2.4” display/ monitor and then transferred when the test is complete.  This allows for faster sampling rates and data retransmission in an event of transmission errors. 

Auto stop logging stops the data logging at a predetermined low value as not to log unnecessary data.

The Excel application works together with a DDE server included.  This application is where the operator will enter the customer and test data.  Once the data is entered the operator can perform a test.  He will start the data logging by pressing the start button on the display/controller.  When the test is complete two files are saved to hard drive, a PDF file of the test performed and an Excel CSV (raw data) file for future use.  You can print the test certificate right from this application or the PDF files can be viewed and printed via a PDF viewer.

 

Panel Meter Version:

 

         

Front Cover   

Inner Panel (Pictured Data Logging Only)

 

Please contact Ted for more info 800 621-8276 or 847 671-7676.